Industries
Every industry wastes energy differently. The data shows where.
Zerowatt runs in 100+ large industrial facilities across India. Here is what the plant’s own data showed at some of them, what changed, and what it was worth.

Industries
Industries we work in
- Power generation
- Cement
- Steel and metals
- Chemicals and petrochemicals
- Refining and fertilisers
- Specialty chemicals
- Pharmaceuticals and API
- Automobile and auto components
- Food, dairy and beverages
- Foundries and secondary steel
- Textiles
- Glass and ceramics
- Pulp and paper
- Multi-plant groups
Also: district cooling, manufacturing, commercial buildings and campuses, water and utilities.
Case studies
What the plant’s own data showed.
- Induction-furnace billet plant · Time-of-day tariff
Heavy melting moved out of the costliest hours.
The share of energy used in the peak tariff band fell from 13.0% to 6.3%, from a change to the melt schedule. No new equipment was needed.Measured · ₹40–50 lakh a yearRead the case study - Foundry · Predictive maintenance
A gearbox replacement became an afternoon’s planned work.
Sand-mixer gearbox vibration spiked past 12 mm/s against a normal reading below 3 mm/s. It was serviced before it seized.Measured alert · about ₹50 lakh failure avoided (estimate)Read the case study - Food processing · Compressed air
A quarter off compressor energy.
491.77 to 368.25 kWh a day, from a zero-cost change to compressor sequencing.Measured on the compressor feeder · about ₹3.01 lakh a yearRead the case study - Food processing · Power factor
A repaired capacitor bank, measured on its own feeder.
Daily feeder energy fell from 199.94 to 60.87 kWh after the repair.Measured on the feeder · about ₹3.43 lakh a yearRead the case study - Sugar cogeneration · Early warning
A turbine gearbox heading the wrong way, about two years early.
Bearing vibration crept up all year while every reading stayed inside the ISO good band.Measured trend · early warning, no saving claimedRead the case study - Hotel · Chillers
A 2 °C setpoint change. About 550 units a day.
Chilled water was reset from 7 °C to 9 °C, with guest comfort checked and held.Reported by the site · about ₹14 lakh a yearRead the case study - Automotive components · Power factor
A capacitor bank’s recorded energy fell after repair.
The bank’s recorded draw went from about 22 kW to about 9 kW. The cause and the size of the fall are being confirmed.Identified · no rupee figure until confirmedRead the case study
Overview
Measured where the change was made
- Billet plantPollution blower draw, furnace off
- Rice millCapacitor bank feeder energy
- Billet plantShare of energy in peak tariff band
- Rice millCompressor feeder energy
| Case study | Measure | Before → after | % lower |
|---|---|---|---|
| Billet plant | Pollution blower draw, furnace off | 70.4 → 8.7 kW | 88% |
| Rice mill | Capacitor bank feeder energy | 199.94 → 60.87 kWh/day | 70% |
| Billet plant | Share of energy in peak tariff band | 13.0% → 6.3% | 52% |
| Rice mill | Compressor feeder energy | 491.77 → 368.25 kWh/day | 25% |
Where the waste hides
Tariff timing
Heavy loads that follow the shift clock instead of the tariff bands pay peak rates for the same output. Re-planning melts around the bands is worth ₹40–50 lakh a year at one billet plant, measured.
- 2 of 7 case studies: Foundry, Sugar cogeneration
Equipment health
Gearboxes and bearings drift long before they fail. One foundry avoided a gearbox failure estimated at about ₹50 lakh. A sugar cogeneration plant has early warning on a turbine gearbox, with no saving claimed yet.
- 2 of 7 case studies: Rice mill, Automotive
Power factor and capacitor banks
A faulty capacitor bank can draw real power instead of correcting it. A repaired bank’s feeder at one rice mill fell from 199.94 to 60.87 kWh a day, about ₹3.43 lakh a year, measured. A similar case at an automotive plant is still being confirmed (identified).
Compressed air
Two compressors both running part-loaded, with neither holding a stable base, waste energy all day. Base-plus-trim sequencing cut compressor energy by a quarter at one rice mill, about ₹3.01 lakh a year, measured.
Idle and auxiliary loads
Fans and blowers that keep running when the process stops add cost and no output. Interlocking a pollution blower to its furnace cut its furnace-off draw from 70.4 kW to 8.7 kW.
Cooling and chillers
Chillers are often set colder than the load needs. A 2 °C setpoint change at one hotel saved about 550 units a day, as reported by the site.
Sector-specific wins
Induction-furnace billet plant
Peak-band energy 13.0% → 6.3% · ₹40–50 lakh a year, measuredMelts were re-planned around the tariff bands with no new equipment. The pollution blower was also interlocked to the furnace.Read the case studyFoundry
Gearbox failure avoided · about ₹50 lakh, one time (client-validated estimate)A vibration alert above 12 mm/s got the sand-mixer gearbox serviced before it seized mid-campaign.Read the case studyFood processing
25% less compressor energy · about ₹3.01 lakh a year, measured on the feederTwo part-loaded compressors were reset to base and trim, at zero cost. A capacitor bank repair at the same mill is measured separately.Read the case study
See it on your own plant.
No monitoring yet?
Zerowatt Vitals
Zerowatt Vitals puts every meter, sensor and machine in the facility live on one platform. Start with one system and add the rest as you go.
Already have monitoring?
Zerowatt Digital Brain
Zerowatt Digital Brain works on your existing monitoring system, DCS, SCADA or historian. Share your historian data and get your findings report.